When receiving a message from modem containing multiple CREG events that
have different format, the parsing happens in the order CREG regexes are
registered, and not in the order the modem sent the events.
That means that when receiving the following URC:
<CR><LF>+CEREG: 2<CR><LF><CR><LF>+CNSMOD: 8<CR><LF><CR><LF>+CEREG: 1,AAAA,01234567,7<CR><LF>
we'd incorrectly parse the `CEREG: 1` before `CEREG: 2`, and remember
the state as searching (2) instead of home (1), which can cause trouble
connecting because of waiting for state to go home which would never
happen again.
This fixes that problem by merging all the regexes together, so the
parsing should properly process the events in matching order in
parse_unsolicited()
Unfortunately changing the regex like this means that
mm_3gpp_parse_creg_response() match info handling also needs to be
reworked: matches number are increased for each regex, so we can
reliably know which regex was matched based on match count.
This is actually cleaner than the old approach that just guessed if nth
field with "item_is_lac_not_stat()", but requires careful testing.
This was validated checking that tests fail if any of the indices is
changed by iterating over them all and running the test:
grep -n 'n_matches -' src/mm-modem-helpers.c | sed -e 's/:.*//' \
| while read lineno; do
echo $lineno
git show HEAD:src/mm-modem-helpers.c \
| awk -v l=$lineno '{ if (NR == l) {
print $1,$2,$3,$4,$5 - 1,";"
} else {
print
}}' > src/mm-modem-helpers.c
ninja -C build src/tests/test-modem-helpers || break
build/src/tests/test-modem-helpers && break
done
A test case was added to make this work, as the Samsung Wave S8500
sample 'act' doesn't seem to actually be a technology value?
(case 36/42 could actually be merged but were kept separate on purpose
for easier maintenance/testing)
Fixes: #1087
Signed-off-by: Dominique Martinet <dominique.martinet@atmark-techno.com>
When sending an unencoded USSD command, the user-supplied string was
spliced directly into the +CUSD AT command. If the string contained
CR or semicolons, it could lead to AT command injection.
Use mm_at_quote_string() to properly quote and escape the USSD
command before sending it.
https://gitlab.freedesktop.org/mobile-broadband/ModemManager/-/work_items/1064
Signed-off-by: Aleksander Morgado <aleksandermj@google.com>
UML290 with firmware L0290VWBB12F.248 doesn't support QMI network
time and crashes when asked for AT network time too quickly after
being plugged in.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
This introduces the "terse" mode during quick suspend/resume, right now
it is used by 3GPP interface to disable unsolicited events, but in
future it can be used by other interfaces as well.
This prevents device to wake-up from suspend for each unsolicited while
still allowing to wake up on calls or SMS messages.
Signed-off-by: biemster <biemster@gmail.com>
Signed-off-by: Bhushan Shah <bshah@kde.org>
Instead of hard-coding a 500ms DTMF tone duration, let applications
use a specific duration at call setup time.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
Instead of getting it from the MMIfaceModemMessaging when the
SMS is stored. This flattens dependencies between MMBaseSms and
MMIfaceModemMessaging.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
This commit moves creation of the MMBaseSms objects out of MMSmsList and up
into MMIfaceModemMessaging (which is already a MMBroadbandModem) and
the MMBroadbandModem subclasses themselves.
This flattens the creation of MMBaseSms objects by passing them down
from the object that creates the SMS parts, rather than having a
convoluted callback scheme relying on MMSmsList and MMBaseSms having
direct knowledge of their owning modem.
The goal is to eventually remove usage of MMBaseModem from MMBaseSms
and MMSmsList so that we can test them more easily.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
Simplify MMBaseSms (making it easier to use from testcases) by
splitting the AT-specific code into MMSmsAt rather than keeping
it in the base class.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
CBM isn't as complicated as SMS, and the CBM class itself doesn't
need to be overridden by QMI/MBIM/etc. Now that the log parent
and connection binding no longer require MMBaseModem we can flatten
the CBM object creation and remove usage of MMBaseModem.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
Continues removing usage of MMBaseModem in a bunch of files
by splitting out bits of its usage to separate interfaces.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
We want ports to be closed as early as possible; so make sure they
are closed in dispose() which is run explicitly by MMDevice when
cleaning up and removing the modem. Otherwise they could stay
open longer than we want, causing problems for suspend/resume.
This caused problems with suspend because cancelling the
MMBaseModem's cancellable triggered an idle handler that held
a reference to the modem, preventing finalize() from running
until after the suspend code was finished, thus preventing
ports from being closed and cleaned up. Closing them in
dispose() handles this.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
This refreshes operator information after manual registration. QMI and
MBIM implementations return operator info along with registration info
so they handle this easily, while with AT-based devices we must run
additional commands to retrieve that after the manual registration has
finished.
Suggested by: Kirill Buksha <kirill.buksha@axians.rs>
Fixes: https://gitlab.freedesktop.org/mobile-broadband/ModemManager/-/issues/971
Signed-off-by: Dan Williams <dan@ioncontrol.co>
If the old IMSI was unavailable because the SIM was locked, but now
is available because the SIM was unlocked, don't treat the SIM
properties change as a hotswap that may trigger dropping and re-probing
the modem.
Signed-off-by: Dan Williams <dan@ioncontrol.co>
Add some mmcli D-Bus timeout slack, making them slightly higher than the
ModemManager internal timeout, to ensure the cli doesn't time out the
D-Bus call when MM succeeds.
For 3GPP scan, some modems appear to have internal 5 minute timeouts,
so ensure MM doesn't time out right before the modem returns results:
ModemManager[282578]: <dbg> [1741054422.321400] [ttyUSB2/at] --> 'AT+COPS=?<CR>'
ModemManager[282578]: <wrn> [1741054722.247806] [modem1] failed scanning networks: Serial command timed out
ModemManager[282578]: <dbg> [1741054724.119770] [ttyUSB2/at] <-- '<CR><LF>+COPS: (1,"T-Mobile","T-Mobile","310260",0),,(0,1,2,3,4),(0,1,2)<CR><LF><CR><LF>OK<CR><LF>'
Signed-off-by: Dan Williams <dan@ioncontrol.co>
Allows setting the renamed `ID_MM_QUALCOMM_FIREHOSE` and
`ID_MM_QUALCOMM_SAHARA` environment variables for all devices.
Signed-off-by: Lukas Voegl <lvoegl@tdt.de>
The CBMs are read via unsolicted events for which we register
an event handler.
We don't enable unsolicted events explicitly as this already happens
via the `+CNMI=*,*,2,*,*` whens setting up unsolicted events in
`modem_messaging_enable_unsolicited_events` (ETSI TS 127 005).
The modem state property update was happening at disabling task context
free time, after the actual task completion has happened.
Avoid wrong assumptions on the modem state value in operations
scheduled after the task completion, in the same way as done in the
enabling sequence.
The modem state property update was happening at enabling task context
free time, after the actual task completion has happened. Due to this,
scheduling a new enable request right after finishing one would end up
with the logic asserting, as the new enable operation would be
scheduled while the modem was still reporting "enabling" state.
ModemManager[7673]: <inf> [1722359278.131123] [modem0] processing user request to enable modem...
**
ERROR:../src/mm-broadband-modem.c:12487:enable: code should not be reached
Bail out! ERROR:../src/mm-broadband-modem.c:12487:enable: code should not be reached
Aborted
The main issue here is how to select the id of the context that is
used for attach in the modem.
We will assume that the lowest cid value for the IP range returned in
the CGDCONT=? test is the one used for the attach context. This
assumption works with modems following the 3GPP specs (with cid=0) and
also in Qualcomm based modems (with cid=1).