Florian Eckert a107de32a8 cinterion: add revision read via AT for the MV31 and MV32
Reading the revsion via the mbim interface returns an incorrect firmware
revsion string. This contains a '\n' character so that the revision looks
like this in 'mmcli'.

Hardware  |            manufacturer: Cinterion
          |            model: Cinterion PID 0x00F1 USB Mobile Broadband
          |            firmware revision: FDE.F0.3.0.1.1.DT.005
          |            062
          |            carrier config: DT

The correct string without '\n' is returned via the AT interface. To fix
the error, the 'mbim' revision interface is overwritten with an AT call
if a MV31 or a MV32 is detected. So we get the correct output via 'mmcli'.

Hardware  |            manufacturer: Cinterion
          |            model: Cinterion PID 0x00F1 USB Mobile Broadband
          |            firmware revision: FDE.F0.3.0.1.1.DT.005.062
          |            carrier config: DT

Signed-off-by: Florian Eckert <fe@dev.tdt.de>