udev-builtin-net_id: use firmware_node/sun for ID_NET_NAME_SLOT

pci_get_hotplug_slot() has the following limitations:
- if slots are not hotpluggable, they are not in /sys/bus/pci/slots.
- the address at /sys/bus/pci/slots/X/addr doesn't contains the function part,
  so on some system, 2 different slots with different _SUN end up with the same
  hotplug_slot, leading to naming conflicts.
- it tries all parent devices until it finds a slot number, which is incorrect,
  and what led to NAMING_BRIDGE_MULTIFUNCTION_SLOT being disabled.

The use of PCI hotplug to find the slot (ACPI _SUN) was introduced in
https://github.com/systemd/systemd/commit/0035597a30d120f70df2dd7da3d6128fb8ba6051
"udev: net_id - export PCI hotplug slot names" on 2012/11/26.
At the same time on the kernel side we got
https://github.com/torvalds/linux/commit/bb74ac23b10820d8722c3e1f4add9ef59e703f63
"ACPI: create _SUN sysfs file" on 2012/11/16.

Using PCI hotplug was the only way at the time, but now 12 years later we can use
firmware_node/sun sysfs file.
Looking at a small selection of server HW, for HPE (Gen10 DL325), the _SUN is attached
to the NIC device, whereas for Dell (R640/R6515/R6615) and Cisco (UCSC-C220-M5SX),
the _SUN is on the first parent pcieport.

We still fallback to pci_get_hotplug_slot() to handle the s390 case and
maybe some other coner cases (_SUN on grand parent device that is not a
bridge ?).
This commit is contained in:
Etienne Champetier
2024-07-21 18:36:37 +01:00
committed by Luca Boccassi
parent 7b5c38a91d
commit 0a4ecc54cb
4 changed files with 74 additions and 11 deletions
+1
View File
@@ -24,6 +24,7 @@ static const NamingScheme naming_schemes[] = {
{ "v253", NAMING_V253 },
{ "v254", NAMING_V254 },
{ "v255", NAMING_V255 },
{ "v257", NAMING_V257 },
/* … add more schemes here, as the logic to name devices is updated … */
EXTRA_NET_NAMING_MAP
+2
View File
@@ -43,6 +43,7 @@ typedef enum NamingSchemeFlags {
NAMING_DEVICETREE_ALIASES = 1 << 15, /* Generate names from devicetree aliases */
NAMING_USB_HOST = 1 << 16, /* Generate names for usb host */
NAMING_SR_IOV_R = 1 << 17, /* Use "r" suffix for SR-IOV VF representors */
NAMING_FIRMWARE_NODE_SUN = 1 << 18, /* Use firmware_node/sun to get PCI slot number */
/* And now the masks that combine the features above */
NAMING_V238 = 0,
@@ -62,6 +63,7 @@ typedef enum NamingSchemeFlags {
* patch later. NAMING_SR_IOV_R is enabled by default in
* systemd version 255, naming scheme "v255". */
NAMING_V255 = NAMING_V254 & ~NAMING_BRIDGE_MULTIFUNCTION_SLOT,
NAMING_V257 = NAMING_V255 | NAMING_FIRMWARE_NODE_SUN,
EXTRA_NET_NAMING_SCHEMES