diff --git a/man/sd_bus_get_fd.xml b/man/sd_bus_get_fd.xml
index 213d139019..eb488b1e6f 100644
--- a/man/sd_bus_get_fd.xml
+++ b/man/sd_bus_get_fd.xml
@@ -26,7 +26,8 @@
sd_bus_get_events
sd_bus_get_timeout
- Get the file descriptor, I/O events and time-out to wait for from a message bus object
+ Get the file descriptor, I/O events and time-out to wait for from a message bus
+ object
@@ -61,65 +62,74 @@
Description
- sd_bus_get_fd() returns the file descriptor used to communicate from a message bus
- object. This descriptor can be used with poll3 or a similar
- function to wait for I/O events on the specified bus connection object. If the bus object was configured with the
- sd_bus_set_fd() function, then the input_fd file descriptor used in
- that call is returned.
+ sd_bus_get_fd() returns the file descriptor used to communicate from
+ a message bus object. This descriptor can be used with
+ poll3
+ or a similar function to wait for I/O events on the specified bus connection object. If the bus
+ object was configured with the sd_bus_set_fd() function, then the
+ input_fd file descriptor used in that call is returned.
- sd_bus_set_fd() sets the file descriptors used to communicate from a message bus
- object. Both input_fd and output_fd must be valid file descriptors.
- The same file descriptor may be used as both the input and the output file descriptor. This function must be called
- before the bus is started.
+ sd_bus_set_fd() sets the file descriptors used to communicate from a
+ message bus object. Both input_fd and output_fd
+ must be valid file descriptors. The same file descriptor may be used as both the input and the
+ output file descriptor. This function must be called before the bus is started.
- sd_bus_get_events() returns the I/O events to wait for, suitable for passing to
- poll() or a similar call. Returns a combination of POLLIN,
- POLLOUT, … events, or negative on error.
+ sd_bus_get_events() returns the I/O events to wait for, suitable for
+ passing to poll() or a similar call. Returns a combination of
+ POLLIN, POLLOUT, … events, or negative on error.
+
sd_bus_get_timeout() returns the time-out in µs to pass to to
- poll() or a similar call when waiting for events on the specified bus connection. The returned
- time-out may be zero, in which case a subsequent I/O polling call should be invoked in non-blocking mode. The
- returned timeout may be UINT64_MAX in which case the I/O polling call may block indefinitely,
- without any applied time-out. Note that the returned time-out should be considered only a maximum sleeping time. It
- is permissible (and even expected) that shorter time-outs are used by the calling program, in case other event
- sources are polled in the same event loop. Note that the returned time-value is relative and specified in
- microseconds. When converting this value in order to pass it as third argument to poll()
- (which expects milliseconds), care should be taken to use a division that rounds up to ensure the I/O polling
- operation doesn't sleep for shorter than necessary, which might result in unintended busy looping (alternatively,
- use ppoll3
- instead of plain poll(), which understands time-outs with nano-second granularity).
+ poll() or a similar call when waiting for events on the specified bus
+ connection. The returned time-out may be zero, in which case a subsequent I/O polling call
+ should be invoked in non-blocking mode. The returned timeout may be
+ UINT64_MAX in which case the I/O polling call may block indefinitely,
+ without any applied time-out. Note that the returned time-out should be considered only a
+ maximum sleeping time. It is permissible (and even expected) that shorter time-outs are used by
+ the calling program, in case other event sources are polled in the same event loop. Note that
+ the returned time-value is relative and specified in microseconds. When converting this value in
+ order to pass it as third argument to poll() (which expects milliseconds),
+ care should be taken to use a division that rounds up to ensure the I/O polling operation
+ doesn't sleep for shorter than necessary, which might result in unintended busy looping
+ (alternatively, use
+ ppoll3
+ instead of plain poll(), which understands time-outs with nano-second
+ granularity).
- These three functions are useful to hook up a bus connection object with an external or manual event loop
- involving poll() or a similar I/O polling call. Before each invocation of the I/O polling
- call, all three functions should be invoked: the file descriptor returned by sd_bus_get_fd()
- should be polled for the events indicated by sd_bus_get_events(), and the I/O call should
- block for that up to the time-out returned by sd_bus_get_timeout(). After each I/O polling
+ These three functions are useful to hook up a bus connection object with an external or
+ manual event loop involving poll() or a similar I/O polling call. Before
+ each invocation of the I/O polling call, all three functions should be invoked: the file
+ descriptor returned by sd_bus_get_fd() should be polled for the events
+ indicated by sd_bus_get_events(), and the I/O call should block for that up
+ to the time-out returned by sd_bus_get_timeout(). After each I/O polling
call the bus connection needs to process incoming or outgoing data, by invoking
- sd_bus_process3.
+ sd_bus_process3.
+
- Note that these function are only one of three supported ways to implement I/O event handling for bus
- connections. Alternatively use
- sd_bus_attach_event3 to attach a
- bus connection to an sd-event3
- event loop. Or use sd_bus_wait3
+ Note that these function are only one of three supported ways to implement I/O event
+ handling for bus connections. Alternatively use
+ sd_bus_attach_event3
+ to attach a bus connection to an
+ sd-event3
+ event loop. Or use
+ sd_bus_wait3
as a simple synchronous, blocking I/O waiting call.
Return Value
- On success, sd_bus_get_fd() returns the file descriptor used for communication. On failure,
- it returns a negative errno-style error code.
+ On success, sd_bus_get_fd() returns the file descriptor used for
+ communication. On failure, it returns a negative errno-style error code.
- On success, sd_bus_set_fd() returns a non-negative integer. On failure, it returns a
- negative errno-style error code.
+ On success, sd_bus_set_fd() returns a non-negative integer. On
+ failure, it returns a negative errno-style error code.
- On success, sd_bus_get_events() returns the I/O event mask to use for I/O event watching.
- On failure, it returns a negative errno-style error code.
+ On success, sd_bus_get_events() returns the I/O event mask to use for
+ I/O event watching. On failure, it returns a negative errno-style error code.
- On success, sd_bus_get_timeout() returns a non-negative integer. On failure, it returns a
- negative errno-style error code.
+ On success, sd_bus_get_timeout() returns a non-negative integer. On
+ failure, it returns a negative errno-style error code.
Errors
@@ -136,8 +146,8 @@
-ECHILD
- The bus connection was allocated in a parent process and is being reused in a child
- process after fork().
+ The bus connection was allocated in a parent process and is being reused
+ in a child process after fork().
@@ -157,8 +167,8 @@
-EBADF
- An invalid file descriptor was passed to sd_bus_set_fd().
-
+ An invalid file descriptor was passed to
+ sd_bus_set_fd().