Let's move it out of cgroup.[ch]. The function primarily compares the
priority values for units, hence let's move the core of it into a new
function unit_compare_priority() in unit.[ch], and then make
compare_job_priority() a local wrapper for it in manager.[ch]
Shorten the code a bit while we are at it.
This is the only function that cgroup.h exports that is prefixed with
cgroup_ where this does not refer to some type such as CGroupContext or
CGroupTasksMax or so. It simply operates on a unit. And it doesn't even
modify a cgroup, but just modifies an nft set.
Hence, to make the naming scheme systematic, change prefix from cgroup_
to unit_, matching the majority of the functions that operate on Unit*
in the file.
They add settings to a CGroupContext, hence give them the expected
context, to make clear they do not operate on anything else than the
structure (i.e. not on a kernel cgroup or so).
systemd's own cgroup hierarchy is special to us, we use it to actually
manage processes. Because of that many calls tha apply to cgroups are
only ever called with the SYSTEMD_CGROUP_CONTROLLER as controller
argument. Let's hence remove the argument altogether.
This in particular touches the kill and xattr routines.
This changes no behaviour, we just drop an argument that is always set
to the same value anyway.
This is preparation to eventually getting rid of the cgroupvs1, because
on cgroupvs2 the cgroup paths do not change for different controllers,
there's only a single hierarchy there.
This makes sure unit_watch_pid() and unit_unwatch_pid() will track
processes by pidfd if supported. Also ports over some related code.
Should not really change behaviour.
Note that this does *not* add support waiting for POLLIN on the pidfds
as additional exit notification. This is left for a later commit (this
commit is already large enough), in particular as that would add new
logic and not just convert existing logic.
performed
systemctl would issue daemon-reload after unit file operations
(enable/disable/preset/...) succeed. However, such operations
are not atomic, meaning that the unit file state could still change
even if the operation generally fails, and the unit_file_state
cached by manager becomes outdated.
Fixes#29341
The benefit of using this setting is that user and group IDs, especially dynamic and random
IDs used by DynamicUser=, can be used in firewall configuration easily.
Example:
```
[Service]
NFTSet=user:inet:filter:serviceuser
```
Corresponding NFT rules:
```
table inet filter {
set serviceuser {
typeof meta skuid
}
chain service_output {
meta skuid @serviceuser accept
drop
}
}
```
```
$ cat /etc/systemd/system/dunft.service
[Service]
DynamicUser=yes
NFTSet=user:inet:filter:serviceuser
ExecStart=/bin/sleep 1000
[Install]
WantedBy=multi-user.target
$ sudo nft list set inet filter serviceuser
table inet filter {
set serviceuser {
typeof meta skuid
elements = { 64864 }
}
}
$ ps -n --format user,group,pid,command -p `systemctl show dunft.service -P MainPID`
USER GROUP PID COMMAND
64864 64864 55158 /bin/sleep 1000
```
New directive `NFTSet=` provides a method for integrating dynamic cgroup IDs
into firewall rules with NFT sets. The benefit of using this setting is to be
able to use control group as a selector in firewall rules easily and this in
turn allows more fine grained filtering. Also, NFT rules for cgroup matching
use numeric cgroup IDs, which change every time a service is restarted, making
them hard to use in systemd environment.
This option expects a whitespace separated list of NFT set definitions. Each
definition consists of a colon-separated tuple of source type (only "cgroup"),
NFT address family (one of "arp", "bridge", "inet", "ip", "ip6", or "netdev"),
table name and set name. The names of tables and sets must conform to lexical
restrictions of NFT table names. The type of the element used in the NFT filter
must be "cgroupsv2". When a control group for a unit is realized, the cgroup ID
will be appended to the NFT sets and it will be be removed when the control
group is removed. systemd only inserts elements to (or removes from) the sets,
so the related NFT rules, tables and sets must be prepared elsewhere in
advance. Failures to manage the sets will be ignored.
If the firewall rules are reinstalled so that the contents of NFT sets are
destroyed, command systemctl daemon-reload can be used to refill the sets.
Example:
```
table inet filter {
...
set timesyncd {
type cgroupsv2
}
chain ntp_output {
socket cgroupv2 != @timesyncd counter drop
accept
}
...
}
```
/etc/systemd/system/systemd-timesyncd.service.d/override.conf
```
[Service]
NFTSet=cgroup:inet:filter:timesyncd
```
```
$ sudo nft list set inet filter timesyncd
table inet filter {
set timesyncd {
type cgroupsv2
elements = { "system.slice/systemd-timesyncd.service" }
}
}
```
This ports over unit_main_pid() + unit_control_pid() to return PidRef*
pointers (which also means the underlying UnitVTable function pointers
are changed accordingly).
This then uses te functions to simplify the unit_kill() call, by
avoiding the kill() vtable indirection and instead just suing
unit_main_pid() and unit_control_pid() directly.
This adds a new structure UnitDefaults which embedds the various default
settings for units we maintain. We so far maintained two sets of
variables for this, one in main.c as static variables and one in the
Manager structure. This moves them into a common structure.
This is most just search/replace, i.e. very dumb refactoring.
The fact that we now use a common structure for this allows us further
refactorings later.
Inspired by the discussions on #27890
When a unit has credentials, stopping the service unmounts the credentials
directory. On shutdown, stopping the service and the corresponding mount
unit may be done mostly simultaneously, and if we invoke umount command soon
after umount() being called on stopping the service, the mount unit will
fail.
This makes Mount.invalidated_state flag set when umount() is called for a path,
and re-read /proc/self/mouninfo before invoking umount command if the flag is set.
Fixes#25527.
Replaces #26959.
As it says on the tin, configures the unit to survive a soft reboot.
Currently all the following options have to be set by hand:
Conflicts=reboot.target kexec.target poweroff.target halt.target
Before=reboot.target kexec.target poweroff.target halt.target
After=sysinit.target basic.target
DefaultDependencies=no
IgnoreOnIsolate=yes
This is not very user friendly. If new default dependencies are added,
or new shutdown/reboot types, they also have to be added manually.
The new option is much simpler, easy to find, and does the right thing
by default.
Let's move this into a vtable callout, so that unit.c doesn't check for
explicit unit types anymore.
(This is preparation for a future where we do a similar check for the
automount logic, or the swap logic.)
Let's decouple execute.c a bit from the Manager object, let's pass the
runtime scope (i.e. the enum that discern invocation for user or system
context) as part of ExecParameters. This makes the scope available in
various functions without having to pass the Manager object in.
This setting allows services to run in an ephemeral copy of the root
directory or root image. To make sure the ephemeral copies are always
cleaned up, we add a tmpfiles snippet to unconditionally clean up
/var/lib/systemd/ephemeral. To prevent in use ephemeral copies from
being cleaned up by tmpfiles, we use the newly added COPY_LOCK_BSD
and BTRFS_SNAPSHOT_LOCK_BSD flags to take a BSD lock on the ephemeral
copies which instruct tmpfiles to not touch those ephemeral copies as
long as the BSD lock is held.
When dbus is overloaded, these messages are easily timedout,
systemd may kill dbus-type service by mistake. This PR
mitigates this problem by increasing the timeout to the
unit's start timeout.
Let's make sure that D-Bus messages are always sent out when pending,
before we might GC a unit/job.
This is kinda a follow-up for 8db998981a,
and a similar logic really applies: GC should only be done if we
processed everything else, generated evertyhing else and really don't
need it anymore.
This is a follow-up for 8db998981a, and
follows a similar logic: a pending OOM event really trumps everything:
we should not GC a unit while it is pending.
The gc_unit_queue is dispatched before the cgroup_empty_queue. Because
of this, when we enter in on_cgroup_empty_event, the unit in
cgroup_empty_queue may already have been freed and we don't clean up the
corresponding cgroup. With this change, we prevent the unit from being
garbage collected if it is in the cgroup_empty_queue.
Previously, if unit_add_dependency_hashmap() failed, then a
one-directional unit dependency reference might be created, and
triggeres use-after-free. See issue #27742 for more details.
This makes unit dependency always bidirectional, and cleanly revert
partial update on failure.
Fixes#27742.
Previously, dependency chain of JoinsNamespaceOf= did not work, e.g.
- a.service has JoinsNamespaceOf=b.service
- b.service has JoinsNamespaceOf=c.service
if, first c.service, next a.service, finally b.service is started,
then a.service is not joined to the namespace of c.service. And, as
mentioned in the document, the namespace used by b.service is not
deterministic.
This makes when searching exsiting namespace to be joined, all units in
the transitive dependency of JoinsNamespaceOf= are checked.
Previously, even if a.service has JoinsNamespaceOf=b.service, the
inverse direction of reference was not introduced.
Hence, a.service is started earlier than b.service, the namespace will
not shared with b.service.
Also, even if a.service had the reference to b.service, b.service did not.
If b.service is freed earlier, then unit_clear_dependencies() does not clear
the reference from a to b, and will cause use-after-free on unit_free() for
a.service.
Let's make JoinsNamespaceOf=b.service in a.service implies the inverse
dependency, i.e. JoinsNamespaceOf=a.service for b.service. Then, we can safely
free b.service.