In Knot 3.2 the nsec3-iterations default was changed to 0 and Knot now
issues a warning if the value is > 0. Let's just use the default value,
since it's not something that's important for our tests.
The RA's Retransmission Timer field was being ignored. This resolves the IPv6
Core Conformance test, v6LC.2.1.5 [1].
Retransmission Timer is a 32-bit unsigned integer. The time, in milliseconds,
between retransmitted Neighbor Solicitation messages. Used by the Address
Resolution and Neighbor Unreachability Detection (NUD) algorithm.
Support setting a default value for the neighbour retransmission timer value with:
[Network]
IPv6RetransmissionTimeSec=<int>
By default, upon receiving a Router Advertisement with the Retransmission Timer
field set to a non-zero value, it will update the kernel's retransmit timer value.
To disable this behaviour, configure the UseIPv6RetransmissionTime= under the
[IPv6AcceptRA] section.
[IPv6AcceptRA]
UseIPv6RetransmissionTime=<bool>
RFC4861: Neighbor Discovery in IPv6
* Section 4.2 RA Message Format.
* Section 6.3.4 Processing Received Router Advertisements
A Router Advertisement field (e.g., Cur Hop Limit, Reachable Time,
and Retrans Timer) may contain a value denoting that it is
unspecified. In such cases, the parameter should be ignored and the
host should continue using whatever value it is already using. In
particular, a host MUST NOT interpret the unspecified value as
meaning change back to the default value that was in use before the
first Router Advertisement was received.
The RetransTimer variable SHOULD be copied from the Retrans Timer
field, if the received value is non-zero.
References
[1] IPv6 Core Conformance Spec (PDF)
Previously, path units would remain in the running state while their
target unit is deactivating. This left a window of time where the target
unit is no longer operational (i.e. it is busy deactivating/cleaning
up/etc) but the path unit would continue to ignore inotify events. In
short: any inotify event that occurs while the target unit deactivates
would be completely lost.
With this commit, the path will go back into a waiting state when the
target unit starts deactivating. This means that any inotify event that
occurs while the target unit deactivates will queue a start job.
With newer versions of AppArmor, unprivileged user namespace creation
may be restricted by default, in which case user manager instances will
not be able to apply PrivateUsers=yes, which is implied by
PrivateTmp=yes in this systemd-run invocation.
With newer versions of AppArmor, unprivileged user namespace creation
may be restricted by default, in which case user manager instances will
not be able to apply PrivateUsers=yes (or the settings which require it).
This can be tested with the kernel.apparmor_restrict_unprivileged_userns
sysctl.
Introduce a _very_ simple DNS server using our internal DNS-related
code, that responds to queries with specifically crafted packets, to
cover scenarios that are difficult to reproduce with well-behaving DNS
servers.
Also, hide the test DNS server behind Knot using the dnsproxy module, so
we don't have to switch DNS servers during tests.
We want to retain *some* of the full paths in order to test more code paths.
But the default should be to use the command name only. This makes the tests
less visually cluttered.