Certain cards support to set their eswitch to switchdev mode. In this
mode for each created VF there is also created so called VF representor.
This representor is helper network interface used for configuration of
mentioned eswitch and belongs to an appropriate PF.
VF representors are identified by the specific value of phys_port_name
attribute and the value has format "pfMvfN" where M is PF function
number and N is VF number inside this PF.
As the VF representor interfaces belong to PF PCI device the naming
scheme used for them is the same like for other PCI devices. In this
case name of PF interface is used and phys_port_name suffix is appended.
E.g.
PF=enp65s0f0np0 # phys_port_name for PF interface is 'p0'
VF=enp65s0f0np0v0 # v0 is appended for VF0 in case of NAMING_SR_IOV_V
REP=enp65s0f0np0pf0vf0 # phys_port_name for VF0 representor is 'pf0vf0'
First as the phys_port_name for representors is long (6+ chars) then the
generated name does not fit into IFNAMSIZ so this name is used only as
alternate interface name and for the primary one is used generic one
like eth<N>. Second 'f0' and 'pf0' in REP name is redundant.
This patch fixes this issue by introducing another naming scheme for VF
representors and appending 'rN' suffix to PF interface name for them.
N is VF number so the name used for representor interface is similar to
VF interface and differs only by the suffix.
For the example above we get:
PF=enp65s0f0np0
VF=enp65s0f0np0v0
REP=enp65s0f0np0r0
This eases for userspace to determine which representor interface
represents particular VF.
Signed-off-by: Ivan Vecera <ivecera@redhat.com>
We use usec_t for storing time value, which is 64bit.
However, usleep() takes useconds_t that is (typically?) 32bit.
Also, usleep() may only support the range [0, 1000000].
This introduce usleep_safe() which takes usec_t.
If multiple devices requested the same device node symlink with the same
priority, then previously we read O(N^2) of files saved in
/run/udev/links.
This makes if the requested symlink already exists with equal or higher
priority, then the symlink is kept, and skip to read all existing files,
except for one related to the current device node, in /run/udev/links.
Hence, the total amount of file read becomes O(N).
This improves performance of testcase_simultaneous_events_2 added by the
previous commit about 30%.
Before (32.8 sec):
```
## 3 iterations start: 11:13:44.690953163
## 3 iterations end: 11:14:17.493974927
```
After (23.8 sec):
```
## 3 iterations start: 11:17:53.869938387
## 3 iterations end: 11:18:17.624268345
```
This is based on the idea and analysis by Franck Bui.
Replaces #25839.
Co-authored-by: Franck Bui <fbui@suse.com>
By default, label_ops is initialized with a NULL pointer which translates
to noop labelling operations. In mac_selinux_init() and the new mac_smack_init(),
we initialize label_ops with a MAC specific LabelOps pointer.
We also introduce mac_init() to initialize any configured MACs and replace all
usages of mac_selinux_init() with mac_init().
Let's make debugging udev triggering a bit easier, by generating debug
log messages whenever we trigger a device, and also when we see the
event in pid1.
When udevadm verify is invoked by an analyzer tool like rpminspect
to verify individual udev rules files, the summary just clutters the
output, so provide an option to turn the summary off.
xHCI host controller may register two (or more?) USB root hubs for USB
2.0 and USB 3.0, and devices under the hubs may have same ID_PATH.
So, to avoid the conflict, let's introduce ID_PATH_WITH_USB_REVISION
that includes the USB revision.
Closes#19406.
When an argument specified to udevadm verify is a directory,
verify all *.rules files in that directory.
Suggested-by: Zbigniew Jędrzejewski-Szmek <zbyszek@in.waw.pl>
When udevadm verify is given an argument that doesn't point to an
existing file, there used to be two diagnostics messages, the first one
at a warning level, and the second one at an error level:
$ build/udevadm verify /no/such/directory
Failed to open /no/such/directory, ignoring: No such file or directory
Failed to parse rules file /no/such/directory: No such file or directory
Fix this by issuing just the error message.
Previously, we first assign alternative names to a network interface,
then later change its main name if requested. So, we could not assign
the name that currently assigned as the main name of an interface as an
alternative name. So, we retry to assign the previous main name as an
alternative name on later move uevent.
However, that causes some confusing situation. E.g. if a .link file has
```
Name=foo
AlternativeNames=foo baz
```
then even if the interface is renamed by a user e.g. by invoking 'ip link'
command manually, the interface can be still referenced as 'foo', as the
name is now assigned as an alternative name.
This makes the order of name assignment inverse: the main name is first
changed, and then the requested alternative names are assigned. And
udevd do not assign alternative names on move uevent.
Replaces #27506.
Meta's resource control demo project[0] includes a benchmark tool that can
be used to calculate the best iocost solutions for a given SSD.
[0]: https://github.com/facebookexperimental/resctl-demo
A project[1] has now been started to create a publicly available database
of results that can be used to apply them automatically.
[1]: https://github.com/iocost-benchmark/iocost-benchmarks
This change adds a new tool that gets triggered by a udev rule for any
block device and queries the hwdb for known solutions. The format for
the hwdb file that is currently generated by the github action looks like
this:
# This file was auto-generated on Tue, 23 Aug 2022 13:03:57 +0000.
# From the following commit:
# https://github.com/iocost-benchmark/iocost-benchmarks/commit/ca82acfe93c40f21d3b513c055779f43f1126f88
#
# Match key format:
# block:<devpath>:name:<model name>:
# 12 points, MOF=[1.346,1.346], aMOF=[1.249,1.249]
block:*:name:HFS256GD9TNG-62A0A:fwver:*:
IOCOST_SOLUTIONS=isolation isolated-bandwidth bandwidth naive
IOCOST_MODEL_ISOLATION=rbps=1091439492 rseqiops=52286 rrandiops=63784 wbps=192329466 wseqiops=12309 wrandiops=16119
IOCOST_QOS_ISOLATION=rpct=0.00 rlat=8807 wpct=0.00 wlat=59023 min=100.00 max=100.00
IOCOST_MODEL_ISOLATED_BANDWIDTH=rbps=1091439492 rseqiops=52286 rrandiops=63784 wbps=192329466 wseqiops=12309 wrandiops=16119
IOCOST_QOS_ISOLATED_BANDWIDTH=rpct=0.00 rlat=8807 wpct=0.00 wlat=59023 min=100.00 max=100.00
IOCOST_MODEL_BANDWIDTH=rbps=1091439492 rseqiops=52286 rrandiops=63784 wbps=192329466 wseqiops=12309 wrandiops=16119
IOCOST_QOS_BANDWIDTH=rpct=0.00 rlat=8807 wpct=0.00 wlat=59023 min=100.00 max=100.00
IOCOST_MODEL_NAIVE=rbps=1091439492 rseqiops=52286 rrandiops=63784 wbps=192329466 wseqiops=12309 wrandiops=16119
IOCOST_QOS_NAIVE=rpct=99.00 rlat=8807 wpct=99.00 wlat=59023 min=75.00 max=100.00
The IOCOST_SOLUTIONS key lists the solutions available for that device
in the preferred order for higher isolation, which is a reasonable
default for most client systems. This can be overriden to choose better
defaults for custom use cases, like the various data center workloads.
The tool can also be used to query the known solutions for a specific
device or to apply a non-default solution (say, isolation or bandwidth).
Co-authored-by: Santosh Mahto <santosh.mahto@collabora.com>