I tried to implement a varlink service using sd-varlink, and
not being able to use the approach with sentinel is exteremely
painful. This is useful internally and likewise externally.
The comment about `SD_BUS_VTABLE_CAPABILITY(CAP_SYS_BOOT)` is
incorrect. To quote @YHNdnzj:
```
nah, the capability-based permission model is a legacy from kdbus. We cannot do it race-freely without it. Please simply drop the comment.
```
Thanks to @YHNdnzj for suggesting this.
The manager_do_set_objective() was doing a bunch of work to
check the `root` path that can already be done via
`json_dispatch_path` so instead of duplicating use the helper.
Thanks to @YHNdnzj for suggesting this.
Drop the _manager suffix for vl_method_{poweroff,{soft,}reboot,
halt,kexec}_manager.
They're unambiguous enough and the power mgmt operations are
not manager-wide but system-wide.
Thanks to @YHNdnzj for suggesting this.
This is not actually used so it doesn't really matter in
practice and the fields are used anyway, but for cleanliness
fix it
Reported on yeswehack.com as YWH-PGM9780-165
Follow-up for 5699a1689b
This commit allows unset pidref when calling manager_log_caller().
With that we can log manager calls even if we cannot resolve the
caller. Currently when we cannot resolve the caller we are just
not logging anything. With this commit we at least log the call
(even though we don't know what caller it was).
Thanks to keszybz for the suggestion.
Extract a common helper varlink_log_caller() and use in the varlink
code when logging the caller of a method. It also logs the method
now that was tried (but failed) to be logged with log_notice just
like manager_log_caller() would do.
I was looking into modifying `manager_log_caller` instead and
accept a NULL pidref but could not log more than the method without
pidref and would make the manager_log_caller slightly less nice.
Thanks to keszybz for suggesting this.
This adds the low-level io.systemd.Manager shutdown support. This
is (much) simpler than the logind one. It mimics dbus but uses
a shared helper for the simple cases.
Note that this is more restrictive than the dbus version. The
dbus version uses SD_BUS_VTABLE_CAPABILITY(CAP_SYS_BOOT) but
the varlink version uses varlink_check_privileged_peer(link).
This is mostly because I'm not sure how to do the equivalent
in a race-free way.
Thanks to Daan for suggesting this.
Loading vmw_vsock_virtio_transport early at boot causes vsock to be
resident before any application opens an AF_VSOCK socket. Because the
kernel skips autoloading when the vsock module is already present,
vsock_loopback never gets loaded automatically, and any subsequent
bind() to VMADDR_CID_LOCAL fails with EADDRNOTAVAIL.
Fix this by explicitly loading vsock_loopback on virtio or VMWare
machines via the new may_have_vsock_looopback() helper, wich covers both
vmw_vsock_virtio_transport and vmware_vsock_vmci_transport case.
vsock_loopback is the only module that registers a transport for
VMADDR_CID_LOCAL (CID 1) and has no hard dependency from any of the
vsock transport modules.
Fixes: #41100
Follow-up for 381c78db491a7c5fad8697543dd36ebe9b848718
We have two places where those fields can be set: config and the dbus
interface. Let's clamp down on the number in both places. But in
principle, we could also be upgrading (through
serialization/deserialization) from an older systemd which didn't
enforce this limit, so also check on deserialization. A user could have
a unit with lots and lots of ExtraFields, but not enough to cause the
issue in #40916. To handle this gracefully, ignore the extra fields,
like we do in the parser. Where the field is used, assert that we are
within the expected bounds.
Fixes#40916.
Reproducer:
```console
$ python3 -c 'from pydbus import SystemBus; from gi.repository import GLib; SystemBus().get("org.freedesktop.systemd1", "/org/freedesktop/systemd1").StartTransientUnit("crash.service", "fail", [("ExecStart", GLib.Variant("a(sasb)", [("/bin/true", ["/bin/true"], False)])), ("LogExtraFields", GLib.Variant("aay", [b"F%d=x" % i for i in range(140000)]))], [])' Traceback (most recent call last):
File "<string>", line 1, in <module>
from pydbus import SystemBus; from gi.repository import GLib; SystemBus().get("org.freedesktop.systemd1", "/org/freedesktop/systemd1").StartTransientUnit("crash.service", "fail", [("ExecStart", GLib.Variant("a(sasb)", [("/bin/true", ["/bin/true"], False)])), ("LogExtraFields", GLib.Variant("aay", [b"F%d=x" % i for i in range(140000)]))], [])
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/lib/python3.14/site-packages/pydbus/proxy_method.py", line 102, in __call__
raise error
File "/usr/lib/python3.14/site-packages/pydbus/proxy_method.py", line 97, in __call__
result = instance._bus.con.call_sync(*call_args)
gi.repository.GLib.GError: g-dbus-error-quark: GDBus.Error:org.freedesktop.DBus.Error.InvalidArgs: Too many extra log fields. (16)
```
We have two places where those fields can be set: config and the dbus
interface. Let's clamp down on the number in both places. But in principle, we
could also be upgrading (through serialization/deserialization) from an older
systemd which didn't enforce this limit, so also check on deserialization. A
user could have a unit with lots and lots of ExtraFields, but not enough to
cause the issue in #40916. To handle this gracefully, ignore the extra fields,
like we do in the parser. Where the field is used, assert that we are within
the expected bounds.
Fixes#40916.
Reproducer:
$ python3 -c 'from pydbus import SystemBus; from gi.repository import GLib; SystemBus().get("org.freedesktop.systemd1", "/org/freedesktop/systemd1").StartTransientUnit("crash.service", "fail", [("ExecStart", GLib.Variant("a(sasb)", [("/bin/true", ["/bin/true"], False)])), ("LogExtraFields", GLib.Variant("aay", [b"F%d=x" % i for i in range(140000)]))], [])'
Traceback (most recent call last):
File "<string>", line 1, in <module>
from pydbus import SystemBus; from gi.repository import GLib; SystemBus().get("org.freedesktop.systemd1", "/org/freedesktop/systemd1").StartTransientUnit("crash.service", "fail", [("ExecStart", GLib.Variant("a(sasb)", [("/bin/true", ["/bin/true"], False)])), ("LogExtraFields", GLib.Variant("aay", [b"F%d=x" % i for i in range(140000)]))], [])
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/lib/python3.14/site-packages/pydbus/proxy_method.py", line 102, in __call__
raise error
File "/usr/lib/python3.14/site-packages/pydbus/proxy_method.py", line 97, in __call__
result = instance._bus.con.call_sync(*call_args)
gi.repository.GLib.GError: g-dbus-error-quark: GDBus.Error:org.freedesktop.DBus.Error.InvalidArgs: Too many extra log fields. (16)
[] has higher precedence than pointer dereference, hence hilarity
ensues as soon as there are multuple images
Originally reported on yeswehack.com as:
YWH-PGM9780-122
Follow-up for dfdeb0b1cb
bus_cgroup_set_tasks_max_scale() used a hand-rolled percentage format
that produced values ~10x too small (e.g., "TasksMax=4.0%" instead of
"TasksMax=40.00%").
On daemon-reload, the incorrect value was re-read, silently reducing
the effective TasksMax by ~10x and causing fork rejections on systems
with high thread counts.
Fix by using the existing PERMYRIAD macros, consistent with memory
property handlers (MemoryMax, MemoryHigh, MemoryLow, etc.).
Fixes: #41009
Follow-up for ab73333c43
Methods that take numeric pid values use 0 to denote the peer,
hence let's log about 0 on PIDREF_AUTOMATIC, -1 if truly unset.
When user creates dropin files via API (e.g. systemctl set-property ...)
we put the dropin directory path into unit_path_cache. Drop those
directories from the cache in unit_free() and prevent memory leak.
Follow-up for fce94c5c56.
History has clearly shown that we're terrible at keeping
the size of the dont_close array up-to-date. Hence let's
step away from a hardcoded max size for that, instead
always collect all fds in the array initializer and
let compiler figure it out, taking advantage of the fact
that close_all_fds() gracefully handles invalid fds in
the 'except' array.
Follow-up for 12001b1bf0
It is part of the keep_fds array already, which is intended
for fds that need to survive until the very end of executor
runtime, i.e. across the second close_all_fds() call.
The owned fds should be closed before close_all_fds() along the lines
of exec_params/runtime_close(), otherwise they would be left dangling
afterwards.
After the update to 260-rc1 in Fedora Rawhide, we get a lot of messages like
this:
systemd[1]: systemd-resolved-monitor.socket:
Failed to create symlink /run/systemd/resolve/io.systemd.Resolve.Monitor →
/run/varlink/registry/io.systemd.Resolve.Monitor, ignoring: Permission denied
The actual issue will need to be fixed too, but let's fix the message first.
While at it, let's rename the variables to be meaningful.
With the previous changes the modes for /tmp/ and /var/tmp/
may come in arbitrary directions, i.e. we may downgrade one
and upgrade another. Hence let's refactor the setup logic
a bit so they're truly independent.
As in the previous commit, checking for both requirements and ordering seems
unnecessary. In practical cases, the mount will be pulled in by the rest
of the transaction, so ordering is the part that matters. (The setup is
racy without the ordering.) If we drop the second check, the admin can
just use After=tmp.mount to achieve the desired behaviour, without needing
to explicitly pull in the unit. This is easier to configure and more robust.
This changes the implementation introduced in
6156bec7a4.
Also actually describe the implemented behaviour in the man page.
In https://github.com/systemd/systemd/issues/28515, multiple people report that
services that have PrivateTmp=yes and DefaultDependencies=no fail to create the
temporary directories under /tmp, when /tmp is e.g. a bind mount or some other
kind of mount that takes more time.
Before PrivateTmp=disconnected was added, we didn't have a nice solution:
DefaultDependencies=no is used to start services very early, so we wouldn't
want to add a dependency on /tmp automatically. With PrivateTmp=disconnected we
have a fairly nice solution. Let's "upgrade" to this mode automatically.
Strictly speaking, it is a small compat break, but in practice it's unlikely to
matter for early-boot services whether their /tmp is private or disconnected.
The dependency on /tmp that is checked is After. I think this is enough,
since any tmp.mount would be pulled in by local-fs.target and the rest of
the transaction anyway, so we don't need to check more than After.
The asserts are relaxed, because now the two settings can now diverge
in either way.
Resolves https://github.com/systemd/systemd/issues/28515.
[yhndnzj: fix unit_add_exec_dependencies() to handle the new
combination; add a comment in exec_needs_sys_admin()]
The only reason why ExecSharedRuntime.(var_)tmp_dir might
be suppressed is when (/var)/tmp/ is listed in InaccessiblePaths=,
in which case mount namespace is needed anyways. Moreover,
the current logic imposes a chicken-and-egg problem:
at various places in pid1 we'd need to check whether
the unit runs in a mountns, but the ExecSharedRuntime
may not be allocated for it just yet.
* Make sure we're not passing NULL to rmdir()
* Remove the inner "tmp" subdir as well, so that callers
can handle this transparently (e.g. exec_shared_runtime_make()
is not aware of the nested rmdir() requirements)
While at it, remove unneeded PROTECT_ERRNO.