The endpoint info of a given MMPortQmi is immutable (it's associated
to the specific kernel driver in use and to the specific physical
interface number of the device).
We'll load it as soon as the kernel device object is set in the port,
and we'll keep it in the private struct so that it can be used at any
time, e.g. by the WDA Get/Set Data Format operations on newest
devices, where the endpoint info TLV is mandatory.
This property will be TRUE if the bearer has the data session
connected through a multiplexed interface.
If the bearer is disconnected, or connected without multiplexing, the
property will report FALSE.
In addition to the amount of bearers a user may connect without
multiplexing enabled (the default until now), we now also expose the
maximum number of bearers a user may connect after enabling
multiplexing over one single network interface (if supported).
The method responsible for creating the MMBearerList is now also
subclassable, so that implementations supporting multiplexing can
provide their own version with their own thresholds.
This property was never initialized with a correct value, we would
always use the same value as used for MaxActiveBearers, which isn't
technically right. Just suggest to ignore this property, and flag
it as deprecated.
In addition to deprecating the API property, we will internally no
longer limit the amount of bearer objects that may be created with
different connection settings. The bearer object exposed in DBus is a
representation of the connection that may be setup, and so we can hold
as many representations as we want as long as the amount of connected
bearers doesn't exceed the maximum amount for each modem.
Leaving around the disconnected modems also serves another purpose.
Each bearer holds information about the amount of times a connection
with it has been attempted, and the amount of data transferred through
it. If we use the Simple.Connect() method to connect the modem using
different bearer settings, we won't lose the information of the past
connection attempts with different settings.
Both the Simple.Connect() and Modem.CreateBearer() are updated to
allow a new 'multiplex' setting in the properties provided by the user
in both of these methods.
The new setting expects a MMBearerMultiplexSupport enum indicating
what kind of multiplex needs the user has:
* none: if multiplex must not be used.
* requested: if multiplex should be used if available.
* required: if multiplex must be used.
The underlying implementations will take care of accepting or
rejecting the setting depending on the system and modem capabilities.
Before reading preferred network list with AT+CPOL?, AT+CPLS=0 is
now invoked first to make sure that the correct PLMN list (i.e.
user-defined) is selected.
On low signal quality conditions, the process of sending the SMS to
the network may take a really long time, way more than the 30s used as
default in some implementations.
We now define a common timeout value of 180s for this operation in all
protocols.
Fixes https://gitlab.freedesktop.org/mobile-broadband/ModemManager/-/issues/328
Enable both AT URCs and QMI indications for messaging events.
This allows to receive text messages during suspend
on the PinePhone with a Quectel EG25 modem.
Prior to this change, hotswap was detected on the primary sim slot only.
After this change, hotswap on any slot triggers reenumeration of the
modem. SIM hotswap events happening on the non-active slot would also
trigger a full modem reprobe. The modem may already have been
connected while the SIM event happens on the secondary slot, and we force
disconnection to reload the inactive SIM info. However, a user would
expect feedback for their SIM action, so we need to reprobe the modem.
The ModemManager1.Sim.PreferredNetworks property contains the preferred
networks (and access technologies, if available) configured to the
SIM card.
This commit implements preferred networks reading with AT+CPOL.
Fix the 'allow roaming' setting comparison, which was breaking the
whole bearer properties comparison logic, and therefore making
Simple.Connect() recreate over and over the bearer with the same
settings.
Fixes 5629f47a59
Use autopep8 utility to resolve issues like spaces before brackets
and wrong hanging indentation.
Also treat objects like boolean variables to check whether they are
None or not.
Instead of creating new clients internally whenever we need them, just
make sure each MMKernelDeviceUdev object keeps a full reference to the
GUdevClient that generated all GUdevDevices.
We already have methods to query for interface specific attributes
like class/subclass/protocol, so add a new one for the interface
number, and make sure we use ATTRS{bInterfaceNumber} to load it
always, instead of assuming the ID_USB_INTERFACE_NUM property is set.
These methods worked in a very strict way for some encodings, and in a
very very loose way for others. E.g. when converting from hex-encoded
UCS-2, we would attempt to convert as much text as we could even if
the input string was truly not even close to UCS-2. This kind of "do
our best" could make sense when processing e.g. the operator name
reported by the modem, as that is some string to show to the user and
there may be no strict requirement to have it perfectly fine. But the
kind of loose comparison done for UCS-2 doesn't make sense e.g. when
converting USSD responses or SMS messages.
Instead of blindly assuming that we can take whatever string given as
valid UTF-8, we'll always attempt to convert from the current modem
charset into UTF-8. Before we were doing this for hex-encoded UCS2,
but not for example for GSM-7.
And due to the now applied GSM-7 conversion, the mf627a/mf627b +COPS
parsing unit tests are updated accordingly, because when converting
from an input string that contains byte 0x40 ('@' in UTF-8) as if it
were GSM-7, the 0x40 is taken as character '¡', encoded as 0xc2,0xa1
in UTF-8).