timer: Do not recalculate monotonic elapse time on clock change
The only clock change that affects monotonic timers is suspend causing CLOCK_MONOTONIC to fall behind CLOCK_BOOTTIME. However, monotonic timers that use CLOCK_BOOTTIME are not intended to have their elapse time changed after a suspend. Hence condition the calculation of monotonic timers’ elapse times on the cause not being a clock change. Fixes #29245
This commit is contained in:
committed by
Lennart Poettering
parent
d63c8ce020
commit
bed9d2587c
+2
-1
@@ -486,7 +486,8 @@ static void timer_enter_waiting(Timer *t, bool time_change) {
|
||||
assert_not_reached();
|
||||
}
|
||||
|
||||
v->next_elapse = usec_add(usec_shift_clock(base, CLOCK_MONOTONIC, TIMER_MONOTONIC_CLOCK(t)), v->value);
|
||||
if (!time_change)
|
||||
v->next_elapse = usec_add(usec_shift_clock(base, CLOCK_MONOTONIC, TIMER_MONOTONIC_CLOCK(t)), v->value);
|
||||
|
||||
if (dual_timestamp_is_set(&t->last_trigger) &&
|
||||
!time_change &&
|
||||
|
||||
Reference in New Issue