Add a service template that adds the machine tag given as its instance
name to the host's machine tags. Whenever an instance is pulled in, the
tag is added; the operation is idempotent.
It talks to hostnamed over Varlink (which is socket-activated), so it
works very early at boot, before the system bus is up. It is ordered
after local-fs.target so that /etc/machine-info can be written, requires
hostnamed's socket and the local filesystems to be available, and does
not run in the initrd.
Teach the "tags" verb to accept arguments prefixed with '+' or '-': a
'+'-prefixed argument adds all of its (colon-separated) tags to the
configured list, a '-'-prefixed one removes them, mapping onto the new
AddAndRemoveTags() D-Bus method. The prefix applies to the whole
argument, so e.g.
hostnamectl tags +foo:bar -quux:ooo
adds foo and bar and removes quux and ooo. Plain (replace) and prefixed
(add/remove) arguments may not be mixed in one invocation.
Add a new D-Bus method on org.freedesktop.hostname1 that incrementally
updates the machine tags instead of replacing the whole list: it takes
two string arrays, one of tags to add and one of tags to remove, and
stores (current ∪ add) \ remove.
This avoids the read-modify-write race that clients would otherwise hit
when several of them each manage a subset of the host's tags.
Factor the tag persistence and the write-error-to-D-Bus-error mapping out
of method_set_tags() into helpers, and add a machine_tags_add_remove()
helper for the set arithmetic, all to be shared with further callers.
Unit-level Condition…= / Assert…= directives that fail prevent activation
entirely, so SuccessAction= / FailureAction= never fire. An ExecCondition=
skip in [Service] runs as part of the activation transition itself, so
the unit goes active → inactive and SuccessAction= is honored.
This asymmetry has tripped users up; document it explicitly in both
systemd.service(5) (ExecCondition= section) and systemd.unit(5)
(SuccessAction= / FailureAction= section) with cross-references.
Fixes: https://github.com/systemd/systemd/issues/42035
Co-developed-by: Claude Opus 4.7 <noreply@anthropic.com>
This is supposed to be useful to mark an interactive user login as a
"break glass" event in the measurement logs, i.e. as in many typically
headless scenerios this indicates debug access or similar.
This allows us to have a separate, more permissive, policy for
cancelling ongoing sysupdate jobs. The new default policy for
cancellation actions is to allow them for the active user, without admin
authentication, because typically the user can just pull the plug on the
computer to cancel a job anyway.
Signed-off-by: Philip Withnall <pwithnall@gnome.org>
Fixes: https://github.com/systemd/systemd/issues/38568
This is supposed to protect our SMBIOS type 11 importing for
credentials. Note that firmwares are supposed to measure SMBIOS anyway
to PCR 1. Alas firmware doesn't really do that in various cases. Hence
let's do so again, for select objects.
This closes a gap where some of the input for OS (i.e. system
credentials places in smbios11) isn't measured properly.
(I really want this to get into v261, because this will fuck up the PCRs
a bit more, and we already have the new separator measurement in v261,
hence there's value in getting this merged at the same time, so that we
don't break the measurements a 2nd time)
For management purposes it's useful to be able to "tag" a machine with
various labels. Let's add a field for that to /etc/machine-info and make
it settable.
Fixes: #38591
This allows us to have a separate, more permissive, policy for
cancelling ongoing sysupdate jobs. The new default policy for
cancellation actions is to allow them for the active user, without admin
authentication, because typically the user can just pull the plug on the
computer to cancel a job anyway.
Signed-off-by: Philip Withnall <pwithnall@gnome.org>
Fixes: https://github.com/systemd/systemd/issues/38568
Currently with FileDescriptorStorePreserve=yes the FD store is kept around
regardless of what happens to a unit, which is useful in many cases. But in
some cases, for example when complex services crash horribly, it's hard to
reason about what was in the intermediate state, and it's better to start
fresh.
Add a new 'on-success' option for the FileDescriptorStorePreserve= setting
that keeps it around only for as long as the unit doesn't go to a persistently
failed state.
This is especially useful in combination with LUO, where we don't want to
keep around LUO sessions created by units that then proceeded to crash and
burn, and might be in a bad state afterwards.
Then, this deprecates
- BindToInterface=
- RelayTarget=
- RelayAgentCircuitId=
- RelayAgentRemoteId=
settings in [DHCPServer] section.
These are gracefully translated as new settings.
This has little to do with host configuration (where it was so far), and
a lot with what being executed, let's move it over.
Note that --help and man page so far differed here quite a bit: the
former had the "Execution" section, the latter didn't. This creates it
in the man page, to bring the two back in sync.
While commit 83c1e8ff5f added support for interactive polkit
authentication in `updatectl`, some users might want to disable that for
some use cases; so add the standard `--no-ask-password` argument.
Signed-off-by: Philip Withnall <pwithnall@gnome.org>
Helps: https://github.com/systemd/systemd/issues/37412
Add --confidential-computing=sev-snp to run the guest as an AMD SEV-SNP
confidential VM. Loads a raw OVMF firmware blob via -bios (SNP doesn't
support the pflash + NVRAM split), attaches a sev-snp-guest object,
and hashes the kernel, initrd and cmdline into the launch measurement
when direct kernel boot is used. Incompatible features (Secure Boot,
CXL, virtio-balloon, SMBIOS credentials) are rejected or disabled; an
attached vTPM must be treated as untrusted by the guest.
The feature is marked experimental in the man page.
Co-developed-by: Claude Opus 4.7 <noreply@anthropic.com>
Signed-off-by: Paul Meyer <katexochen0@gmail.com>
as specified by the haproxy documentation:
https://www.haproxy.org/download/1.8/doc/proxy-protocol.txt
only protocol v1 is implemented for now, protocol v2 is binary,
and will be implemented in the future.
the proxy protocol allows the destination/target to know the
address/port of the client connectiing.
in nginx it's supported by enabling the `proxy_protocol` parameter to
the `listen` directive.
Some drivers (currently mlx5_core) expose sub-functions (SFs) of a PCI
Physical or Virtual Function as auxiliary devices that carry a stable
`sfnum` sysfs attribute (the user-defined SF number passed to `devlink
port add ... sfnum N`). Their leaf devices (net, infiniband, ...)
currently inherit the parent PF/VF's `ID_PATH` and the SF netdev falls
through to the kernel-assigned `eth<N>` name.
Two patches:
1. `udev-builtin-path_id`: prepend an `sf-<N>` token when the walk
crosses an aux device with `sfnum`, so SF leaf devices get an `ID_PATH`
distinct from the parent PF/VF (e.g. `pci-0000:c1:00.0-sf-88`). Aux
devices without `sfnum` keep the pre-patch behaviour, so existing
`ID_PATH` values are unchanged and the patch needs no naming-scheme gate
(path_id is unversioned).
2. `udev-builtin-net_id`: name SF host netdevs analogously to SR-IOV VF
host netdevs — walk to the parent PCI function and append a
single-character `S<sfnum>` suffix. SFs hosted on SR-IOV VFs (VF-SF) get
both suffixes chained on the PF's base name (`enp193s0f0v0S88`). Gated
behind `NAMING_SUBFUNC` / `NAMING_V261`. Man page
(`systemd.net-naming-scheme(7)`) updated.
The patches apply to any driver that exposes its SF leaf devices below
an aux device exposing `sfnum`.
Validated on mlx5 hardware: PF, VF, SF-on-PF (`enp8s0f0S88`,
`pci-0000:08:00.0-sf-88`). VF-SF case verified with a fake-sysfs setup
since this is not supported by any real device and is more a theoretical
use case.
Add COREDUMP_CODE to the fields captured by systemd-coredump. This makes
it possible for system administrators to filter coredumps based on si_code,
which describes the reason why a given signal was sent.
For example, to find processes killed due to invalid permissions
(SEGV_ACCERR):
$ journalctl COREDUMP_SIGNAL=11 COREDUMP_CODE=2
I've decided to add the value of si_code to the 'Signal: ' line of
coredumpctl info:
Signal: 11 (SEGV) si_code: SEGV_ACCERR
Allow users to allow DHCPv6 unreachable/blackhole routes (installed
for delegated prefixes) into a specific routing table, analogous to
the existing RouteTable= in [DHCPv4] and [IPv6AcceptRA].
The config parser config_parse_dhcp_or_ra_route_table() is extended
with an AF_UNSPEC ltype discriminator for DHCPv6 (AF_INET6 is already
taken by NDISC/RA). link_get_dhcp6_route_table() follows the same
pattern as link_get_dhcp4_route_table() and link_get_ndisc_route_table(),
falling back to the VRF table when not explicitly set.
In dhcp_request_unreachable_route(), the table is applied only for
NETWORK_CONFIG_SOURCE_DHCP6 routes (the uplink unreachable aggregates),
not DHCP_PD routes (per-subnet routes on downstream interfaces), matching
the intent of the feature. The !route->table_set guard avoids overriding
a table already set by the route code.
Some drivers (currently mlx5_core) expose sub-functions (SFs) of a PCI
Physical Function as auxiliary devices. Each SF carries a host network
interface that sits below the aux device in sysfs:
/sys/devices/.../<PF BDF>/mlx5_core.sf.<idx>/net/eth<N>
Because the network device's immediate parent is the aux device and not
a PCI device, names_pci() bails out and these interfaces fall through
to the kernel-assigned eth<N> name, which is not stable across reboots,
module reloads or topology changes.
The naming applies when the SF network device's direct sysfs parent is
the aux device that exposes sfnum, i.e. the kernel driver passes the
aux device to SET_NETDEV_DEV(). mlx5_core does so. ice's
ice_sf_cfg_netdev() currently passes the parent PF's PCI device, so ice
SF network devices sit as siblings of the PF rather than below the aux
device and fall outside this precondition; pending a kernel change in
ice to mirror mlx5's SET_NETDEV_DEV(netdev, &adev->dev), they continue
to receive the kernel-assigned name as they do today.
The aux device exposes 'sfnum', the user-defined sub-function number
(the value passed to "devlink port add ... sfnum N"), which is stable
and unique within its parent PF. The aux device's direct sysfs parent
is the PF's PCI device.
Treat an SF host network device analogously to an SR-IOV VF host
network device: walk to the parent PCI function, derive the base name
from there, then append a single-character "S<sfnum>" suffix. Lowercase
's' is already taken (slot) and the existing grammar uses one character
per token, so 'S' is the best option.
E.g. for an SF whose parent PF is at PCI 0000:c1:00.0 and which was
added with "sfnum 88":
ID_NET_NAME_PATH=enp193s0f0S88
ID_NET_NAME_SLOT=enp193s0f0S88
This is parallel to how SR-IOV VFs get a "v<N>" suffix on top of the
parent PF's name.
Gate the new behaviour behind NAMING_SUBFUNC and NAMING_V261. Document
the new suffix in both the ID_NET_NAME_SLOT and ID_NET_NAME_PATH
grammars in systemd.net-naming-scheme(7) and add a v261 history entry.
Co-developed-by: Claude Opus 4.7 <noreply@anthropic.com>
Introduce COREDUMP_CODE as a new captured field alongside the existing
COREDUMP_SIGNAL. While COREDUMP_SIGNAL identifies the signal number that
terminated the process, COREDUMP_CODE provides the reason the signal was sent.
For example, a process terminated by SIGSEGV due to invalid permissions would
produce COREDUMP_SIGNAL=11 and COREDUMP_CODE=2 (SEGV_ACCERR).
The kernel exposes coredump_code via pidfd starting with v7.1:
https://git.kernel.org/torvalds/c/701f7f4fbabbf4989ba6fbf033b160dd943221d5
System administrators can find both the signal and code in coredumpctl info:
$ coredumpctl info | grep Signal:
Signal: 11 (SEGV) si_code: SEGV_MAPERR
Signed-off-by: Emanuele Rocca <emanuele.rocca@arm.com>
`NFTSet` is supposed to be in `Service` instead of `Unit` section. The current example leads to `Unknown key 'NFTSet' in section [Unit], ignoring` in systemd logs.
Add CacheSize= option to [Resolve] section of resolved.conf to allow
configuring the maximum number of entries in the per-scope DNS cache.
The default remains 4096 entries. Setting this to 0 disables caching
(similar to Cache=no).
CacheSize= is only read when Cache=yes or Cache=no-negative. When
Cache=no, caching is fully disabled regardless of CacheSize=.
Changes:
- Add cache_size field to Manager struct
- Parse CacheSize= from resolved.conf via gperf
- Thread cache_size through dns_cache_put() and helper functions
- Replace hard-coded CACHE_MAX with the configurable cache_size
- When cache_size is 0 or Cache=no, flush cache and skip caching
- Add man page documentation for the new option
- Add unit tests for cache size enforcement
Co-developed-by: Claude <claude@anthropic.com>
When there is a NOTIFY_SOCKET, and FDs are received from the
payload following the FD Store protocol, forward them up the
chain to the service manager that is managing nspawn.
This allows FD Store persistence across container restarts,
and can chain up for user managers as well to survive restarting
those, or reexecs, and in the future reboots too via LUO.
Add a new test case to exercise the PID1 -> user session -> nspawn -> payload
chain.
In order to allow FD Stores of user units to survive a user
session restart, propagate FDs received via the protocol up one
level from user to system manager via sd_notify.
And the other way around, propagate them down via LISTEN_FDS
tagging them with the unit name so that the child manager can
inject them in the appropriate unit.
Ensure units that are dead or not loaded can get FDs added to
their stores, and that they are correctly propagated once the
unit is started or loaded. When the unit is not loaded we don't
know what the FD max limit is, so simply increase it for each FD
injected, and then when the unit is realised prune it down to
match the unit's now available config in case the limit is lower
than the number of FDs in the store.
Each FD sent up or down is assigned a monotonic index, and the manager
also sends a JSON map that associates the index with the original
unit and FDNAME:
{
"unit-name.service": [
{ "name": "fdname1", "index": 1 },
{ "name": "fdname2", "index": 2 }
],
...
}
This allows the manager to assign back the FDs to the appropriate
unit using the appropriate name, given the FDNAMEs are not unique.
When the kernel hands the command line to PID 1, any KEY=VALUE assignment
whose KEY does not contain a '.' is exported as an environment variable
(with '-' replaced by '_') rather than passed as an argument. Mimic the
same split in --boot mode so kernel-cmdline-style arguments passed after
the container path behave as they would on a real boot.