broadband-bearer: no need for explicit flow control cleanup on disconnect
We're already configuring the flow control we expect when running mm_port_serial_reopen(), which will keep the udev-selected flow control or will otherwise reset to no flow control when the TTY is in command mode.
This commit is contained in:
committed by
Dan Williams
parent
a19be8952f
commit
727567cf58
@@ -1418,16 +1418,6 @@ data_flash_cdma_ready (MMPortSerial *data,
|
||||
|
||||
mm_port_serial_flash_finish (data, res, &error);
|
||||
|
||||
/* Cleanup flow control */
|
||||
if (self->priv->flow_control != MM_FLOW_CONTROL_NONE) {
|
||||
GError *flow_control_error = NULL;
|
||||
|
||||
if (!mm_port_serial_set_flow_control (MM_PORT_SERIAL (data), MM_FLOW_CONTROL_NONE, &flow_control_error)) {
|
||||
mm_dbg ("Couldn't reset flow control settings: %s", flow_control_error->message);
|
||||
g_clear_error (&flow_control_error);
|
||||
}
|
||||
}
|
||||
|
||||
/* We kept the serial port open during connection, now we close that open
|
||||
* count */
|
||||
mm_port_serial_close (data);
|
||||
@@ -1560,16 +1550,6 @@ data_flash_3gpp_ready (MMPortSerial *data,
|
||||
|
||||
mm_port_serial_flash_finish (data, res, &error);
|
||||
|
||||
/* Cleanup flow control */
|
||||
if (self->priv->flow_control != MM_FLOW_CONTROL_NONE) {
|
||||
GError *flow_control_error = NULL;
|
||||
|
||||
if (!mm_port_serial_set_flow_control (MM_PORT_SERIAL (data), MM_FLOW_CONTROL_NONE, &flow_control_error)) {
|
||||
mm_dbg ("Couldn't reset flow control settings: %s", flow_control_error->message);
|
||||
g_clear_error (&flow_control_error);
|
||||
}
|
||||
}
|
||||
|
||||
/* We kept the serial port open during connection, now we close that open
|
||||
* count */
|
||||
mm_port_serial_close (data);
|
||||
|
||||
Reference in New Issue